Full scale test of AE detection for broken cable

Brief:Full-size cable loading and wire breaking experiment on the cable (hanger) produced by a cable factory

Full scale test of acoustic emission detection for broken wires of bridge cables

On July 1, 2022,

Qingcheng Acoustic Emission Research (Guangzhou) Co., Ltd. was invited by a research institute to conduct a full-size cable loading and wire breaking experiment on the cable (hanger) produced by a cable factory and the actual bridge hanger with 1:1 production.  The two-week full scale test of acoustic emission detection for broken wires of bridge cables was successfully completed with remarkable results. Experimental data show that RAEM1 can be unattended and remote automatic monitoring of broken wires to ensure that no single broken wire is missed, and can automatically push broken wires and the rate of broken wires to mobile phones and mailboxes. 

  • Bridge special sensor installation:

  • RAEM1 Internet of Things Acoustic Emission Collector:

  • RAEM1 Principle of Iot Acoustic Emission System:

  • Qingcheng Internet of Things platform to check the broken wire data:


Some experimental results:

 

断丝序号

断丝时间
(年-月-日 时-分-秒.毫秒)

能量
(kPj)

振铃计数

累计断丝根数

断丝率

监测报警准确率

实验1

1

2020-07-01 10:19:28.002

11986

175

8

6.01%

100%

2

2020-07-01 10:19:56.264

17502

209

3

2020-07-01 10:20:23.310

15702

193

4

2020-07-01 10:20:30.589

11501

187

5

2020-07-01 10:20:35.842

22272

211

6

2020-07-01 10:20:54.539

13748

199

7

2020-07-01 10:20:03.479

13455

192

8

2020-07-01 10:20:14.212

15446

187

实验2

1

2020-07-01 10:31:16.511

14311

183

17

12.78%

100%

2

2020-07-01 10:31:36.324

26892

213

3

2020-07-01 10:31:48.274

10186

190

4

2020-07-01 10:31:53.430

17032

209

5

2020-07-01 10:31:56.521

13325

187

6

2020-07-01 10:32:00.881

22072

204

7

2020-07-01 10:32:08.468

14983

195

8

2020-07-01 10:32:10.541

29296

224

9

2020-07-01 10:32:27.976

18101

205

实验3

1

2020-07-01 10:47:46.621

15926

182

26

19.55%

100%

2

2020-07-01 10:48:05.754

14360

196

3

2020-07-01 10:48:07.765

15337

206

4

2020-07-01 10:48:12.710

14609

192

5

2020-07-01 10:48:16.878

20007

247

6

2020-07-01 10:48:18.385

14429

230

7

2020-07-01 10:48:57.937

12278

176

8

2020-07-01 10:49:11.875

15527

204

9

2020-07-01 10:49:19.881

24730

226

  • Wire breaking and wire breaking rate alarm push:

  • Email alarm push:

  • SMS alarm push:

     

Conclusion:  

The acoustic emission signal of broken wire has high amplitude, high energy, high ring count, high RMS and obvious characteristics, which can be distinguished from most noise signals.  The data and results of this experiment show that acoustic emission testing can effectively detect the phenomenon of broken wires.  The data and results of this experimental study also prove that the RAEM1 iot acoustic emission monitoring system can accurately and effectively monitor the phenomenon of wire breakage, and the 100% accuracy of the experimental data of wire breakage has no missing report.  RAEM1 can be unattended remote automatic monitoring of broken wire, so as not to miss a single broken wire phenomenon, and can automatically push broken wire and broken wire rate to mobile phone and email.  

The experimental data show that the energy and RMS value of the broken wire signal at the anchor head are much larger than that at the casing.  The data show that a single sensor installed at the unjacketed anchor head position can effectively detect wire breakage throughout the cable.

Contact

Hotline:+86-20-32290092Cel:+86 19128609186WeChat/Whatsapp:+86 19128609186Email: sales2@ae-ndt.comSkype:jessicajia

9:00-18:00 (UTC+8)

Follow Us

YouTube

Facebook

Copyright©2023 QAWRUMS Ltd. Privacy Policy